Accessibility Tools

15 June 2003

The TFS candle filter system in practical testing

The new TFS Twin Flow System was introduced for the first time in 2001 at the drinktec-interbrau. In the meantime, scientifically based practical experiences with the system have been made. The TU Munich-Weihenstephan subjected a TFS system at the Paulaner Brewery in Munich to extensive acceptance testing with respect to technology, microbiology, performance and consumption.

The Memminger Brewery AG converted its existing candle filter system to TFS. The following technical article describes the TFS candle filter system and reports on the results established in these breweries.

Register replaces perforated plate

In the TFS System from Steinecker a new filtrate run-off register replaces the conventional perforated plate for the fastening of the filter candles.

Current issue

BRAUWELT International

Receive the most important BRAUWELT news three times a month for free.
Newsletter archive and informations
Your data is secure and will not be passed on to third parties. You can revoke your consent at any time by clicking on the unsubscribe link at the end of the newsletter.

By clicking on "Subscribe to newsletter," you confirm that you have read our privacy policy and accept the processing of your data as described therein.

Current issue

BRAUWELT International

Receive the most important BRAUWELT news three times a month for free.
Newsletter archive and informations
Your data is secure and will not be passed on to third parties. You can revoke your consent at any time by clicking on the unsubscribe link at the end of the newsletter.

By clicking on "Subscribe to newsletter," you confirm that you have read our privacy policy and accept the processing of your data as described therein.

BRAUWELT on tour

Craft Brewers Conference & BrewExpo America
Date 20 Apr 2026 - 22 Apr 2026
EBC Congress
06 Sep 2026 - 09 Sep 2026
kalender-icon